Modern technology

Used in the staircase control circuit, according to the set delay time of turning on and off the circuit, in three-phase star-delta motor start, automatically controls the start delay, automatically converts circuits for a set time.

Product quality is guaranteed by the Rhenes inspection and quality department. In addition, time relays from each batch are selectively checked at Avitron Polska.

It has built-in microcontrollers, knob setting, adjustment of start time and conversion time. LED indicator shows work status. Star-delta conversion control. Mounting also on a DIN rail.

Multi Range Time Relays

Technical Data
Standard IEC60050-445
Approval CE
Accuracy (class) Repeat error: 1%-2% max
Setting error: 5%-10% max
Voltage error: 1 %-5% max
Temp. error: 2% max
Rated voltage (V DC/AC ) 12-240
Indicator operation ON,UP Operation; Time Operation Flicker
O/P contact capacity (A) 5
Mechanical life (times) 106
Żywotność elektryczna (czasy) 105
Reset time 0.1-0.5 second max
Self-consumed power (VA) 2
Ambient temperature ('C) -10-+55
Ambient humidity 35-85%RH

EvRT1

Technical data of EVR1 ST:

  • Rated control supply voltage: 110V, AC220V, AC380V
  • Rated power consumption: AC <1.5VA DC <1W
  • Delay range: 0.1s-10min
  • Conversion time: 20ms-300ms
  • Accuracy settings: <5%
  • Accuracy: <0.2%
  • Repeatable power on interval:> 200ms
  • Electrical life: 105
  • Mechanical life: 105
  • Installation height: <2000m
  • Capacity of configuration contacts (A): 5A
  • IP class: IP20
  • Contact capacity Ue / le: 240V / 1.5A, AC380V / 0.95A
  • Contact capacity 2NO

Technical data of EVR1 SC:

  • Rated control supply voltage: AC110V, AC220V 50 / 60Hz
  • Rated power consumption: 1.5VA / 0.7W
  • Delay range: 0.5s-20min
  • Accuracy settings: <± 10%
  • Accuracy: <± 5%
  • Number of neon lamps 50 pcs, max.
  • 50mA neon lamp current, max.
  • Electrical life: 105
  • Mechanical life: 105
  • Capacity of configuration contacts (A): 16A
  • Installation height: <2000m
  • IP class: IP20

EvRT2

Technical data:

  • Rated control voltage: DC12V, DC24V, AC110V, AC220V, AC380V
  • Power supply: AC / DC24V-240V 50 / 60Hz
  • Rated power consumption: 1.5VA / 1W
  • Electrical life 105
  • Mechanical life 106
  • Installation height: <2000m
  • IP class: IP20
  • Configuration contact capacity (A): 1C / O, 2C / O - 16A, 3C / O - 8A
  • Contact capacity: 1 C / O, 2C / O, 3C / O
AVITRON © 2019 - All rights reserved.